SIM2 MultimediaC3X1080RS-232C CONTROL SPECIFICATIONSRev. 1.1 (30 January 2008)
2.3 Status CommandsStatus Commands may be used to get the current value of the main projector parameters.Status CommandsParameter CommandProjector Sta
• Bytes 23 and 24 (labeled FF FF in the table above) contain the Failure Condition (if any):OK (No failure) 00 00Lamp Failure 00 01Fan Failure (Lamp C
Lamp StatusWhen then unit is On, the returned packet (27 byte long) is described in the following table:1E BE EF 10 13 00 .. .. 01 01 00 01 01 15 01 0
3 ExamplesSend the simulated ‘SWITCH ON FROM STANDBY’ Remote Control keycodeRemote Control allows Switching on from Standby via the key ‘0’.Send the c
SIM2 Multimedia S.p.A.Viale Lino Zanussi, 11 — 33170 Pordenone — ItalyTel. +39.0434383281 — Fax [email protected] USA Inc.101
ContentsContents 21 Introduction 31.1 Setting up the RS-232C Serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 Execution of
1 IntroductionThis document describes how to interface the SIM2 C3X1080 projector with a Home Theater control system(or a PC) over a direct serial con
1.2 Execution of the commandCommand execution time may vary from 0.1 to 2.0 seconds, depending on the operation that have beenrequested.If the project
2 CommandsIn this section, serial commands (and respective responses) are listed. Commands (and responses) are seriesof bytes (numbers holding values
Aspect Normal BE EF 02 06 00 2A F4 83 01 00 00 00 00Aspect Anamorphic BE EF 02 06 00 9D F5 84 01 00 00 00 00Aspect Letterbox BE EF 02 06 00 4C F4 85 0
ContrastAction Command ResponseIncrement BE EF 1A 0C 00 9D 5E 01 00 02 00 00 00 00 00 00 00 00 00 OK 20 XX 00Decrement BE EF 1A 0C 00 58 0F 01 00 03 0
Color Management: PrimariesAction Command ResponseSet Native BE EF 1A 0C 00 68 FE 41 00 00 00 00 00 00 00 00 00 00 00 OK 20 XX 00Set HDTV BE EF 1A 0C
XX is the hex representation of the value of Gamma.Example: if the returned value is XX = 04 then Gamma is set to EN5.OverscanAction Command ResponseI